Preliminary monitoring results indicate that some odour
controls at the existing plant are working effectively and others require
maintenance:
- The
existing biofilter is effectively reducing odours
- The
chemical scrubber requires maintenance
- The
biological scrubber also requires maintenance.
Improvements underway now:
- FCPCC
operators are currently troubleshooting repairs on the chemical scrubbers.
FCPCC operators will focus on the biological scrubbers next.
- We are
testing a charcoal filter on the septage receiving station. VIU will
sample this in the upcoming months to assess its effectiveness.
Additionally, these odour
control upgrades are being incorporated into the project design:
- The
odour upgrades will aim to minimize or eliminate nuisance odours so they
are not detectable outside of the property boundary:
- Existing
biofilter media will be upgraded to treat foul air from the expansion
- A new
biofilter will be added to treat foul air from the trickling filter
- Trickling
filter window and roof seals will be improved.
Share We Have Reached the 60% Detailed Design Milestone on Facebook
Share We Have Reached the 60% Detailed Design Milestone on Linkedin
Email We Have Reached the 60% Detailed Design Milestone link
A full set of project drawings
is under review by RDN engineering and
operations. The next step in the design process will be a 90%
Detailed Design package, followed by the final Issued for Tender (IFT) drawings
and specification package.
Share October 9, 2019 - Public Information Session on Facebook
Share October 9, 2019 - Public Information Session on Linkedin
Email October 9, 2019 - Public Information Session link
For updated information on this project, please attend our Public Information Session:
Wednesday, October 9, 2019
4PM – 6PM
Oceanside Place - Multipurpose Room (Upstairs)
830 Island Highway West, Parksville
Share Opportunities to Learn More - Office Hours and Open House on Facebook
Share Opportunities to Learn More - Office Hours and Open House on Linkedin
Email Opportunities to Learn More - Office Hours and Open House link
Want to learn more about this project?
Drop in to one of our
office hours at Oceanside Place or join us for our Open House at the French Creek Pollution Control Centre.
Office Hours:
Oceanside Place in the Meeting Room (upstairs)
830 Island Highway West, Parksville
Tuesday, May 14, 2019
10:00 – 12:00
Thursday, May 23, 2019
2:00 – 4:00
Tuesday, May 28, 2019
10:00 – 12:00
Thursday, June 6, 2019
2:00 – 4:00
Open House:
French Creek Pollution Control Centre
957 Lee Road, Parksville
Saturday, June 8, 2019
10:00 – 12:00
Tours of the plant will be available
Share March 27, 2019 - Public Information Session on Facebook
Share March 27, 2019 - Public Information Session on Linkedin
Email March 27, 2019 - Public Information Session link
For more information on this project, please attend our Public Information Session:
Wednesday, March 27, 2019
4PM – 6PM
Oceanside Place - Multipurpose Room (Upstairs)
830 Island Highway West, Parksville
Share VIU to Monitor Odours at FCPCC on Facebook
Share VIU to Monitor Odours at FCPCC on Linkedin
Email VIU to Monitor Odours at FCPCC link
The RDN has partnered with the VIU Applied Environmental Research Laboratories to implement a state of the art
odour monitoring program to fingerprint French Creek Pollution Control Centre’s
current odour emissions.
This monitoring program will:
- Use mobile mass spectrometry instrumentation to analyze molecular fingerprints associated with specific odour-producing substances
- Map chemical concentrations of a set of target compound classes including reduced sulfur compounds, amines, hydrocarbons and volatile fatty acids. Mapping will be done both at the French Creek Pollution Control Centre and in the surrounding neighborhood
- Analyse the odourants associated with human activities and natural sources including wastewater treatment, green waste production, agriculture, as well as natural marine and freshwater sources
- Assess the seasonal variability in odour sources and regional distributions
- Recommend potential odour control measures.
The proposed monitoring program will
start in March 2019 and run for a year with multi-day sampling campaigns in
spring, summer, fall and winter. Program results will inform the design of the
upgrades and produce recommendations to improve air quality, reduce odour
complaints related to FCPCC, and enhance the overall quality of life for
neighbouring residents and visitors.
Share Contract for Detailed Design, Tendering and Construction Services Awarded on Facebook
Share Contract for Detailed Design, Tendering and Construction Services Awarded on Linkedin
Email Contract for Detailed Design, Tendering and Construction Services Awarded link
At the Regular Board Meeting on July 24, 2018, the RDN Board awarded the Engineering Services contract for the detailed design, tendering and construction services for the French Creek Pollution Control Centre Stage 4 Expansion Project and Odour Control Upgrades to AECOM for $2,506,980.
Share Peer Review Exercise will Optimize Plant Design and Performance on Facebook
Share Peer Review Exercise will Optimize Plant Design and Performance on Linkedin
Email Peer Review Exercise will Optimize Plant Design and Performance link
Preliminary design of the FCPCC Expansion and Odour Updgrade Project was completed in 2018. A peer review of the preliminary design will optimize the detailed design
phase, going on now, so the constructed plant performs well and operates
efficiently.
Share Secondary Treatment Process Selected on Facebook
Share Secondary Treatment Process Selected on Linkedin
Email Secondary Treatment Process Selected link
Process selection was completed in 2011 and recommended that the expansion provide secondary treatment with activated sludge technology. Preliminary design, completed in 2018, recommended that activated sludge be provided using Combined Treatment Units where bioreactors are on the outside of the unit and secondary clarifiers on the inside of the unit.